Re: CIF core revision list 6 _exptl_crystal_density_meas_temp_lt

  • To: Multiple recipients of list <coredmg@iucr.org>
  • Subject: Re: CIF core revision list 6 _exptl_crystal_density_meas_temp_lt
  • From: Howard Flack <Howard.Flack@cryst.unige.ch>
  • Date: Fri, 27 Jun 2003 11:11:06 +0100 (BST)
> loop_
>        _example
>        _example_detail
>  '_exptl_crystal_density_meas_temp_lt   300'
> ;          The density was measured as some unspecified temperature below room
>            temperature.

  Totally horrid. It means that they did not measure the density and
they did not measure the temperature either. They were sitting in the
pub drinking beer at some unspecified temperature.
  You don't want to give examples of what is totally unacceptable
experimental practice.


H.